CYQUANT LDH FLUO 200 1 KIT,C20302,Applied Biosystems

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 1YS9235
品牌型号 Applied Biosystems C20302
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
微信扫一扫,手机采购
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Product Line: CyQUANT™
Shipping Condition: Dry Ice
Detection Method: Fluorescent
For Use With (Equipment): Microplate Reader
Format: 96-well plate
储存
• Reagent Mix, 1 vial
• Reporter Mix, 1 x 12 mL
• Lysis Buffer, 1 x 2.5 mL
• Stop Solution, 1 x 12 mL
• LDH Positive Control, 1 x 6 µL

Store at -20°C, protect from light.

描述

The CyQUANT LDH Cytotoxicity Assay, fluorescence, is a fluorescent assay that provides a simple and reliable method for determining cellular cytotoxicity. Lactate dehydrogenase (LDH) is a cytosolic enzyme present in many different cell types that is released into the cell culture medium upon damage to the plasma membrane. The CyQUANT LDH Cytotoxicity Assay, fluorescence, provides the reagents to accurately and quantitatively measure this extracellular LDH.

The CyQUANT LDH Cytotoxicity Assay, fluorescence, features include:
Convenient—add-mix-read assay protocol for adherent and suspension cells, including 3D cell models
Accurate—provides a quantitative measurement of LDH release
Flexible—ideal for high-throughput screening, monitor cytotoxicity from the same sample over time
Robust—formulation with highly purified resazurin results in a large assay dynamic range

LDH is a cytosolic enzyme present in many different cell types and is a well-established and reliable indicator of cellular toxicity. Damage of the plasma membrane results in a release of LDH into the surrounding cell culture medium. This extracellular LDH can be quantified by a coupled enzymatic reaction in which LDH catalyzes the conversion of lactate to pyruvate via NAD+ reduction to NADH. Diaphorase then uses NADH to reduce resazurin to resorufin that can be detected using an excitation of 560 nm and emission of 590 nm. The level of resorufin formation is directly proportional to the amount of LDH released into the medium.

As a consequence of the synthesis and manufacturing processes, all resazurin-based reagents contain a detectable amount of resorufin contamination. The amount of contamination can vary greatly between sources of the material and manufacturing conditions, contributing to differences in detectable background fluorescence. More importantly, the contaminating resorufin reduces the signal to background ratio and dynamic range of the assay. An innovative process was developed that removes the contaminating resorufin, resulting in the highly pure resazurin used in the CyQUANT™ LDH Cytotoxicity Assay, fluorescence.

The CyQUANT LDH Cytotoxicity Assay, fluorescence, provides the reagents needed for the simple, reliable fluorescence-based quantification of cellular cytotoxicity. The kit can be used with different cell types, including 3D cell models, to measure cytotoxicity mediated by chemical compounds as well as cell-mediated cytotoxicity. Since LDH in the medium is the indicator of cellular cytotoxicity, the assay can be used to monitor cytotoxicity from the same sample over time. To perform the assay, an aliquot of the cell culture medium is transferred to a new plate and the reaction mixture is added. After a 10-minute incubation, the reaction is stopped by adding Stop Solution and fluorescence is measured using a microplate reader.

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询